Vaillant Turbomax Problems Help:
Vaillant Turbomax Problems Help:
Call: Mark 07515-687740
E-mail: mark@vaillantservice.co.uk
vaillantservice.co.uk
Early Models, up to 1999-2000
VU / VUW 182 / 242 / 282E and /1E
Black plastic facia, metal side opening door
Later Models, 2000 - 2005/6
VU / VUW 202 / 824 / 828E
Plastic drop down door, green, amber and red neons.
Green or Beige controls
Diverter Valves:
Usually need replacing every 5 years or so.
Symptoms:
Hot water only works when the boiler is in heating mode, and running.
Plate Heat Exchanger:
Symptoms:
Fluctuating hot water temperature. Hot/cold/hot/cold etc.
Usually more noticeable in the shower.
Remedy:
Can sometimes be rescued with removal and flushing. Indicates heating system is blocking up boiler.
Replacement may be required, and system filter required for future protection.
Plate Heat Exchanger:
Symptoms:
Fluctuating hot water temperature. Hot/cold/hot/cold etc.
Usually more noticeable in the shower.
Remedy:
Can sometimes be rescued with removal and flushing. Indicates heating system is blocking up boiler.
Replacement may be required, and system filter required for future protection.
Diverter Valves:
Symptoms:
Intermittent hot water, heating comes on when turned off.
Hot water is constant, but only luke warm.
Radiators start warming up when in hot water operation.
Radiators come on in the middle of the night.
Remedy: Replace
Warning!
It is a criminal offence to work on a gas appliance if you are not qualified, and licensed to do so.
ALWAYS consult the manufacturers user instructions for guidance. The instructions above are for guidance only. If unsure of any procedures, call a boiler specialist, who holds the relevant qualifications, and GAS Safe Registration.
Distinctive RED neon indicating major fault condition.
Call someone....